Suitable for installation with plastic and metal carriers
Specifications:
Application
Application
coding of workpiece carriers in routing conveyors
Operating temperature (active) [°C]
-25...85
Peak temperature (passive) [°C]
160; (duration of test: 1 x 35 h)
Electrical data
Operating frequency [MHz]
0,125
Memory size [bit]
224
Max. read cycles
unlimited
Max. write cycles
100000
Operating conditions
Ambient temperature [°C]
-25...85
Storage temperature [°C]
-40...130
Protection
IP 67
Tests / approvals
Shock resistance
DIN IEC 68-2-2740 g 18 ms
Vibration resistance
DIN IEC 68-2-610 g 10...2000 Hz
MTTF [years]
2854
Mechanical data
Weight [g]
1.4
Dimensions [mm]
Ø 12 / L = 2
Materials
PPS black
Remarks
Remarks
peak temperature 1 x 35 hStorage temperature 1 x 1000 hshock 6 Achsen je 2000 Schocksvibration 3 Achsen je 2,5 h
Pack quantity
1 pcs.
Other data
read/write distance (mm)
positioning of the ID tagreadwriteDTA100overhead5...205...20DTA101overhead5...20–DTA200front side2525DTA201front side25–DTA300front side4040DTA301front side40–